TechKnowSurge
CompTIA Server+ 1.2 CompTIA A+ Core 1 3.3 CompTIA Security+ 3.4
InteractiveSecurityFree

RAID Level Architect

Size a RAID array by hand — usable capacity, minimum drives, guaranteed fault tolerance, and which level a stated requirement actually calls for.

Complete this interactive to capture a CTF flag worth 5 points.

About this interactive

RAID arguments are usually settled by arithmetic, not preference: at a fixed drive count each level returns a different usable capacity and a different number of failures it can absorb, and the right answer falls out of those two numbers once you have them. This drill makes you produce them. It asks for usable capacity across RAID 0, 1, 5, 6 and 10 at various drive counts and drive sizes, for the minimum drive count each level requires, and for the number of drive failures each is guaranteed to survive whichever drives fail — which for RAID 10 is one, not two, because both drives of a single mirrored pair can be the ones that go. Then it reverses the question the way a real build does: given four drives and a redundancy requirement, which level leaves the most storage, and given a capacity target and a drive size, how many drives does the array need. Every answer is typed and graded exactly, and a miss shows the formula that produced it rather than only the number.

What you'll learn

Aligned to

CompTIA Server+
1.2 Given a scenario, deploy and manage storage.
CompTIA A+ Core 1
3.3 Given a scenario, select and install storage devices.
CompTIA Security+
3.4 Explain the importance of resilience and recovery in security architecture.

Key terms

Redundant Array of Independent Disks
RAID
A data storage technology that combines multiple physical drives into a logical unit to improve performance, provide redundancy, or both, depending on the RAID level chosen. Common levels include RAID 0 (striping for speed), RAID 1 (mirroring for redundancy), and RAID 5 (striping with parity).
RAID 0
A RAID configuration that stripes data across two or more drives to improve read and write performance, but provides no fault tolerance — losing any one drive loses all data.
RAID 1
A RAID configuration that mirrors identical data simultaneously across two drives, providing full redundancy so that the array continues operating if either drive fails.
RAID 5
A RAID configuration that stripes data and distributed parity across three or more drives, providing read performance gains and the ability to survive the failure of any single drive.
RAID 6
A RAID configuration that stripes data across four or more drives with two independent sets of parity, allowing the array to survive the simultaneous failure of any two drives.
RAID 10
A nested RAID configuration (RAID 1+0) that applies mirroring at the drive level first, then striping across mirrored pairs, providing both redundancy and performance.
Striping
A RAID technique that splits data across multiple drives sequentially to improve read and write performance.
Mirroring
A RAID technique that writes identical copies of data to two or more drives simultaneously so that if one drive fails the other contains a complete working copy; provides redundancy without improving write speed.
Parity
Calculated redundancy data stored across drives in certain RAID levels that allows the array to reconstruct lost data mathematically if a single drive fails.
Fault Tolerance
A design property that allows a system to continue operating correctly even when one or more of its components fail, achieved through techniques such as redundancy and failover.
Redundancy
The duplication of critical components or systems to increase reliability and availability.

Topics

Interactive Calculation Raid Storage Fault Tolerance Redundancy Capacity Planning

About TechKnowSurge

TechKnowSurge builds IT and cybersecurity professionals through hands-on, concept-first training built around real understanding — not memorization. Free interactive tools, structured programs, and 25+ years of real-world experience, all in one place.

Explore free tools and programs →