About this interactive
The fiber connectors the lesson shows:
- **LC (Lucent connector):** the small one, with a latch you press, like an RJ45's clip.
- **SC (subscriber connector):** a square body that pushes in and snaps.
- **ST (straight tip):** a round barrel with a bayonet slot; push it on and twist to lock.
- **Simplex and duplex:** one connector, one fiber; two clipped together, two fibers.
- **UPC and APC:** how the two fiber ends meet. Ultra physical contact meets square on; angled physical contact meets at a slant (8 degrees on real connectors).
The tolerances are tighter than copper's, which is why few people fit their own fiber connectors.
What you'll learn
- Pick out the LC (Lucent connector), SC (subscriber connector) and ST (straight tip) fiber connectors, and a duplex pair against a single simplex connector
- Tell a UPC (ultra physical contact) end face, square to the fiber, from an APC (angled physical contact) end face, cut at a slant
Aligned to
CompTIA Network+
1.5
Compare and contrast transmission media and transceivers.
Cisco CCST Networking
3.1
Identify cables and connectors commonly used in local area networks
CompTIA A+ Core 1
3.1
Explain basic cable types and their connectors, features, and purposes.
Key terms
- Lucent Connector
LC
- A small form-factor fiber optic connector widely used in data centers and telecommunications equipment, featuring a push-pull latching mechanism and half the footprint of an SC connector.
- Subscriber Connector
SC
- A push-pull fiber optic connector with a square form factor commonly used in single-mode and multimode fiber network installations. SC connectors are widely used in telecommunications and campus backbone cabling, though they have been largely replaced by LC connectors in high-density applications.
- ST Connector
ST
- The Straight Tip connector, a fiber optic connector that uses a bayonet-style twist-lock mechanism to secure the connection.
- Ultra Physical Contact
UPC
- A fiber optic connector polishing standard where the end-faces are polished flat and mated straight on to minimize signal loss.
- Angled Physical Contact
APC
- A fiber optic connector polishing standard where the end-faces are polished at an angle, reducing back-reflection and signal loss compared to UPC.
Topics
Fiber Connectors
Lc Connector
Sc Connector
St Connector
Upc
Apc